Dimming Lights Manually w/Sensor Dimming System CEM

Mindwatering Incorporated

Author: Tripp W Black

Created: 11/05/2013 at 02:51 PM

 

Category:
Lighting System
Unison Dimmer System

Issue:
Sending Unison Lighting Control System's network switch is not functioning and sending commands to CEM+ dimmer system.

Workaround:
1. Open the rack door of the SEM+ Dimming System
2. Click the icon of the light bulb on the right of the admin panel.
3. At the Dimmer - Set / Release Levels message, click the check-mark (enter) button.
4. At the Set / Release Levels heading, there is a range presented of rack lights to control (e.g. 1 to 90 max in our case).
a. The left number is the starting light circuit number. Set the initial to 1, if not already set to 1. Use the up and down buttons as needed. Click check button to tab over to the right range field.
b. The right number is the ending light circuit number in the range. Using the up and down buttons, set the end value to the desired number, such as 90. Click the check button to go to the next screen.
c. Now the heading will update to include the word Level. Use the up and down arrows to choose the lighting % (dim to bright). Click check button to commit, apply the change.

To turn off.
Click the reset power button on the left of the admin panel (looks like a wave).